Atlas GP40

Scale:
HO Scale


This installation uses the following decoder:


This installation of TCS DP2X Decoder is for HO Scale Atlas GP-40 and was performed by A.G.

The upper picture shows the beautiful Atlas GP-40 with its shell on.
Grasp the shell part as shown above and pull it straight up.
This picture illustrates the original light board with the DCC-ready plug installed. In the upper left corner of the DCC socket you can see small triangle mark - that is the "pin # 1" indication.
Plug the DP2X into the DCC socket so that the decoder's pin #1 (see the manual that comes with the decoder for more info) is lined up with " first pin indicator" of the board.

Important Soldering Tip

Please do not use any flux either liquid or paste on the mother board. Over time, the acidic properties of liquid or paste flux will begin eating away at the fiberglass PCB and will damage it. Use only Rosin-core solder or no-clean flux approved for electronics use.

TCS recommends the use of Kester "44" Sn63 Pb37, .015" diameter Rosin-core solder. Kester part number 24-6337-0007.

You can order this solder from the following retailers:
Digikey - PN:KE1110-ND
Techni-Tool - PN:488SO6775

Other solder tips

When stripping wire, only strip a tiny little bit of the insulation. Strip no more than a 1/32 of an inch. When the wire gets tinned with solder, the insulation will shrink back more. Try to not expose any more wire than half the length of the solder pad at most. In no case should solder or exposed wire wire ever be outside the boundary of the the solder pad you are attaching a wire to.
Click here for important information on properly Stripping and Tinning wire